154
CONTROL TAB
The Control Tab allows you to configure pin assignments for the user-definable pins on Control/Status Port A and
Control/Status Port B.
All models implement control/status using DB-25 pin ports on the back panel, and GPIO (General Purpose Input
Output) with active low/pull to ground inputs and open collector outputs. For details, refer to Appendix B and the
Control/Status Ports section of Appendix D: Specifications.
The control ports enable external devices to access the Converge/Converge Pro serial command set, including
common functions such as volume control, muting, room combining, and preset changes. All devices connected
via the E-bus can be controlled from a single control/status port on any of the devices.
Accessing the Control Tab
To access command control, press the Control Tab on the Tab Bar in Console.
The Control tab of the Console main screen shows a graphical representation of Control/Status Port A. The pins
numbered in blue are user-definable command pins; the pins numbered in green are status pins. Control interface
functionality and pin programming are explained in the following sections.
User-Definable Pins
The user-definable pins provide control via contact closure, and status via open collector functions in the unit. There
are two user-definable pins on the B port of every unit. The number of user-definable pins on the A port varies by
model, as summarized in the following table:
Model User-Definable Pins
Control/Status Port A
User-Definable Pins
Control/Status Port B
880 16 2
880T 16 2
880TA 16 2
840T 20 2