Field Name Values Description
Auto Disconnect
Automatic
Disconnect-
ion
-- The Automatic Disconnection group
provides four options which can be
used singly or in any combination.
Jitter Value 1-65535
milli-
seconds
The Jitter Value defines the average
inter-arrival packet deviation (in
milliseconds) before the call is
automatically disconnected. The default
is 300 milliseconds. A higher value
means voice transmission will be more
accepting of jitter. A lower value is less
tolerant of jitter.
Inactive by default. When active,
default = 300 ms. However, value must
equal or exceed Dynamic Minimum
Jitter Value.
Call Duration 1-65535
seconds
Call Duration defines the maximum
length of time (in seconds) that a call
remains connected before the call is
automatically disconnected.
Inactive by default.
When active, default = 180 sec.
This may be too short for most
configurations, requiring upward
adjustment.
Consecutive
Packets Lost
1-65535 Consecutive Packets Lost defines the
number of consecutive packets that are
lost after which the call is automatically
disconnected.
Inactive by default.
When active, default = 30
Network
Discon-
nection
1 to 65535
seconds;
Default =
30 sec.
Specifies how long to wait before
disconnecting the call when IP network
connectivity with the remote site has
been lost.