Fujitsu SRS-1050 Telephone User Manual


 
SRS-1050 Testing ( Appendix C
Page C-4
SELF TEST (MEMORY/LINE)
VOICE & DATA ALL GOOD
Program and Loop Switch
Test
If your SRS-1050 has the optional
data terminal adapter, pressing 5
displays the status of the Program
(PRG) and Loop switches that are
a part of the TA. The display
looks like this:
SELF TEST (PROGRAM SW/LOOP SW)
PROG RAM: OFF LOOP:NOR
Pressing the Program switch on
the back of the set changes
PROG RAM: OFF to PROG
RAM: ON. Pressing the Loop
switch changes LOOP: NOR to
LOOP: TEST. See your Data
User's Guide for the function of
these switches.
Exiting Test Mode
To exit test mode, remove power
and reapply it.
Table C-1 Self-Test Result Codes
Display Message Test Result
S/M ERROR CODE (01) SMCM, RAM, ROM test failed.
S/M ERROR CODE (02) Line SIU test failed.
S/M ERROR CODE (03) Line SIU test timed out.
S/M ERROR CODE (04) Line NT test failed; message received
does not match message sent.
S/M ERROR CODE (05) Line NT test timed out.
S/M ERROR CODE (06) Line NT test failed; no response
received.
S/M ERROR CODE (07) SMCM test timed out.
S/M ERROR CODE (07) SMCM, RCM test timed out.
RCM (02)
RCM ERROR CODE (01) RCM RAM test failed.
RCM ERROR CODE (02) RCM test timed out.
VOICE ALL GOOD All tests passed.
VOICE & DATA ALL GOOD All tests passed (with data terminal
adapter).