186
Command List
Item
Command
Default
Read all codes
A0 --
UPC only
J1 --
UPC + 2 digits of supplemental only
J2 --
UPC + 5 digits of supplemental only
J3 --
EAN only
J4 --
EAN + 2 digits of supplemental only
J5 --
EAN + 5 digits of supplemental only
J6 --
DTF only
J7 --
ITF only
J8 --
CODE39 only
A2 --
NW-7 (CODABAR) only
A3 --
CODE93 only
A5 --
CODE128 only
A6 --
1.
Readability
of code
MSI/Plessey only
A7 --
UPC Enable read
R1 Yes
UPC + 2 digits of supplemental Enable read
R2 --
UPC + 5 digits of supplemental Enable read
R3 --
EAN Enable read
R4 Yes
EAN + 2 digits of supplemental Enable read
R5 --
EAN + 5 digits of supplemental Enable read
R6 --
DTF Enable read
R7 Yes
ITF Enable read
R8 Yes
CODE39 Enable read
B2 Yes
NW-7 (CODABAR) Enable read
B3 Yes
CODE93 Enable read
B5 --
CODE128 Enable read
B6 --
2.
Adding
readable
code
MSI/Plessey Enable read
B7 --
CODE39
Not calculate C/D
Calculate C/D
Transfer C/D
Not transfer C/D
Not transfer start/stop code
Transfer start/stop code
C0
C1
C2
C3
D0
D1
Yes
--
Yes
--
--
Yes
NW-7 start/stop code
Not transfer
Transfer ABCD/TN*E
Transfer abcd/tn*e
Transfer ABCD/ABCD
Transfer abcd/abcd
F0
F1
F2
F3
F4
--
--
--
--
Yes
3.
Data
transfer
format
ITF/DTF C/D
Not calculate C/D
Calculate C/D
Transfer C/D
Not transfer C/D
G0
G1
G2
G3
Yes
--
Yes
--