Avaya 555-245-600 IP Phone User Manual


 
Mid-market to large enterprise
Issue 6 January 2008 101
S8700 IP-PNC configuration
Figure 33: S8700 IP-PNC standard configuration
Figure notes:
1. Two S8700-series Servers. One server
is in a active mode, and the other
server is on standby.
2. Duplication Interface. The Ethernet
connection between the two
S8700-series Servers.
3. A dedicated Ethernet connection to a
laptop computer. This connection is
active only during on-site
administration or maintenance, and the
Services interface can link to the
non-active server through a telnet
session.
4. Connection from the servers to the
Ethernet switch.
5. Ethernet switch. A device that provides
port multiplication on a LAN by
creating more than one network
segment.
6. UPS units. Two UPS units are required
7. Port Network. An optional
configuration of Media Gateways that
provides increased port capacity.
8. IPSI. A circuit pack that transports
control messages over IP. The IPSI
circuit pack is used so that the
S8700-series Server can communicate
with the Port Networks.
9. Customer LAN.
10. TN799DP Control-LAN (C-LAN)