Avaya 555-233-116 Telephone User Manual


 
Data modules and asynchronous data units
555-233-116
48 Issue 4 October 2002
Understanding RS-232
communications
To install a data module, you have to set up the device to work with RS-232
devices.
NOTE:
Data modules, PGATE boards, printers connected through data modules,
SATs connected through data modules, and anything related to the X.25
connectivity protocol are not supported on the S8300 or S8700 Media
Server platforms.
The RS-232 communications protocol defines a communications link as a Data
Communications Equipment (DCE) device and a Data Terminal Equipment (DTE)
device connected by an RS-232 cable. The send and receive pins on DCE
equipment (pins 2 and 3) are reversed on DTE equipment, so that the DCE
transmit pin connects to the receive pin of the DTE and vice versa.
Generally, the term DCE is applied to devices that mediate between customer
equipment and the carrier or network. Such devices include modems, data
modules, and data units. DTE describes devices that provide a user interface for
data communications, such as dumb terminals and PCs. When configured as
DTE, data modules are used for asynchronous modem pooling. When configured
as DCE, data modules are analogous to modems in that they link a device such
as a terminal or PC (DTE) to DEFINITY.
To install a data module correctly, you identify the connected equipment as DCE
or DTE and do one of the following:
Configure the modem for a DTE or DCE connection
Install a null-modem converter
Detailed instructions are provided for each modem type, beginning on page 49.