Avaya 555-233-116 Telephone User Manual


 
1145B power supply
Issue 4 October 2002
37555-233-116
6. Remove the output power cable between the 1145B and the 1147B units.
The cable will not be reused.
7. Connect the P1 connector end of the T-cable to the bottom power
distribution unit.
8. Connect the P2 connector to the top distribution unit.
9. Connect the P3 connector to the 1145B.
10. Power-up the 1145B as described on the label on the side of the unit.
Figure 4. Expanded power distribution unit
1. Wall-mounting plate
2. Optional 1146 power distribution unit
3. T cable (H600-347-G7)
4. Standard 1146 power
distribution unit
5. 1145B power unit
1145 Power Unit
1149 Battery
On Battery Reserve
Charging Battery
Output Power On
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
-48V -48V
RTN RT N
Unit No.
Connected To:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
-48V -48V
RTN RT N
Unit No.
Connected To:
0004_1 PDH 06259