Avaya 555-233-116 Telephone User Manual


 
Property management system (PMS)
555-233-116
226 Issue 4 October 2002
Figure 63. Connections to an asynchronous data unit
Connecting a terminal and/or journal
printer
You can connect customer data terminals, host computers, and/or an optional
journal printer in either of two ways.
Using data modules
1. Configure printer or terminal in accordance with the recommendations in
the vendors documentation.
2. Configure the data module for the printer or terminal, using the instructions
in Chapter 4, ‘‘Data modules and asynchronous data units’’.
3. Identify the port associated with the data unit or data module using the
Data Module Form (see ‘‘Administer the data modules’’ on page 95).
1. Z3A1 or Z3A2 ADU
2. 4-pair line cord
3. 103A or modular wall jack
4. Analog telephone
5. Satellite site or adapter location
6. Station side blue or white field
7. System side
8. Data module
9. TXT
10. TXR
11. PXT
12. PXR
13. Tip
14. Ring
15. To analog line circuit pack
16. To data line circuit pack
17. 25-pin RS-232-D connector (male)
18. Main distribution frame
2
2
3
9
10
10
11
11
12
12
6
8
14
15
LINE
V.35
POWER
RS-366/RS-232
9
13
7
0002
_
1 RBP 062596
1