Panasonic KX-TD816 Telephone User Manual


 
2.5 Auxiliary Connection for Power Failure Transfer
112 General Installation
2.5 Auxiliary Connection for Power Failure Transfer
2.5.1 Auxiliary Connection for Power Failure Transfer
Power Failure Transfer connects specific single line telephones to selected outside lines in the
event of system power failure, as follows:
KX-TD816
Outside Line 01 — Extension (T, R) Jack 01 /
Outside Line 02 — Extension (T, R) Jack 02 /
Outside Line 05 — Extension (T, R) Jack 09 /
Outside Line 06 — Extension (T, R) Jack 10
Connections of outside lines 1, 2 and the respective extensions require no auxiliary connection.
Outside lines 05 and 06 require auxiliary connection to implement this feature.
KX-TD1232
Outside Line 01 — Extension (T, R) Jack 01 /
Outside Line 02 — Extension (T, R) Jack 02 /
Outside Line 03 — Extension (T, R) Jack 09 /
Outside Line 04 — Extension (T, R) Jack 10 /
Outside Line 09 — Extension (T, R) Jack 17 /
Outside Line 10 — Extension (T, R) Jack 18
Connections of outside lines 01 through 04 and the respective extensions require no auxiliary
connection. Outside lines 09 and 10 require auxiliary connection to implement this feature.
Insert the modular plugs of connection cords (4-conductor wiring) to the modular jacks of 4-
CO Line Unit and Extension Line Unit 1.
(In the case of KX-TD816, one Extension Line Unit is available.)
Panasonic
4CO
DIGITAL SUPER HYBRID SYSTEM
PFT PARTS
2CO W/PFT
2CO
8EXT
DIGITAL SUPER HYBRID SYSTEM
2CO
PFT ports
R: Ring
T: Tip
T2 R1 T1 R2
View of TEL Jack (Outside Line)