Avaya 40DHB0002USBG Caller ID Box User Manual


 
Wallboard Installation and Maintenance Wallboard 10
Compact Contact Center Installation & Maintenance
40DHB0002USBG Issue 1 (11/14/2001) Wallboard Installation and Maintenance
Page 43
Baud Rate
The Baud Rate can be changed to 1200, 2400, 9600 or 19200 using the
dip-switch. The Baud Rate is set using switches 5 and 6.
5 6 Baud Rate
ON ON 1200
OFF ON 2400
ON OFF 9600
OFF OFF 19200
Ensure the Baud rate is set to 9600.
Test Functions
Test functions are provided to assist installation engineers. These are
selected on the dips-witches. Test functions are selected using switches 7
and 8.
If switch 7 and 8 are OFF at power reset:
78
ON ON Freeze Display
OFF ON Alternating ON/OFF Blocks of LED's
ON OFF Stripes
OFF OFF Normal Operation
If switch 7 and 8 are ON at a power reset:
78
ON ON Information Screen
OFF ON Stripes
ON OFF Alternating ON/OFF Blocks of LED's
OFF OFF Freeze Display