System & Station
Program 02 – Station Physical Port Display and/or Change
3-2 Strata DK Programming 5/00
Program 02 – Station Physical Port Display and/or
Change
Processor Type: DK14, DK40i, all RCTUs and BCUs
Program Type: Station
Initialized Default: Logical port number = physical port number
Program 90, 91-1, or 91-9 initializes Program 02
Program 02 Overview
Program 02 enables you to enter a logical port to display the associated physical port. You then
have the option to assign a new physical port to the logical port. (To return ports to their initialized
settings, see Programs 90 and 91.)
Notes
● Record port locations on Program 04 record sheet.
● The system allows only like ports to be reassigned (see below).
● RCIU/RCIS circuit assignments to CO lines are not affected by Program 01 and 02.
✱ ✱ ✱ ✱ 6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Processor [PDN] Port Range Processor [PDN] Port Range
DK14 000~009 B1CU 000~055
DK40i 000~027 B2CAU/BU 000~111
RCTUA 000~031 B3CAU/BU 000~191
RCTUBA/BB 000~079 B5CAU/BU 000~335
RCTUC/D 000~239
RCTUE/F 000~335
Allowed Not Allowed
Digital-to-Digital Ports (KCDU-QCDU-PDKU-
PDKU-RDSU Ports)
Attendant Console (DK424, DK424i only),
DSS, BGM or Amplified Conference Ports
should not be reassigned
Electronic-to-Electronic Ports (PEKU-PEKU-
PESU Ports)
Door Phone Ports (004, 012, 020, 028) should
not be reassigned
Standard Tel to Standard Tel Ports (QSTU-
KSTU-PSTU-RSTU-PESU-RDSU/RSTS)
Tie/DID Line Ports – should not be reassigned
PDKU to PEKU – cannot be exchanged
PSTU to PDKU – cannot be exchanged
PEKU to PSTU – cannot be exchanged
To Save existing Physical Port
6SNU
SELECT = Logical Port Number
The physical port number associated
with the logical telephone port displays
after the logical port number is entered.
Enter new Physical Port
to change existing Physical Port