System & Station
Program 37 – Ring Transfer (Camp-on) Recall Time
Strata DK Programming 5/00 3-107
System & Station
Program 37 – Ring Transfer (Camp-on) Recall Time
Processor Type: DK14, DK40i, all RCTUs and BCUs
Program Type: Station
Initialized Default: Assigns Ring Transfer Recall Time of 32 seconds to all ports
Program 37 Overview
If a busy or ringing station does not answer a call sent to it via ring (blind) call transfer (lines or
[DNs]), the station originating the ring (blind) transfer is recalled after an amount of time
determined with this program. This time (011~999 seconds) is set independently for each
originating station port. Initialized data sets all stations for a 032-second recall time. Ring Transfer
must first be enabled for the system with Program 10-1, LED 07 On.
✱ ✱ ✱ ✱ 6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Processor Type Port Range Processor Type Port Range
DK14 000~009 B1CU 000~055
DK40i 000~027 B2CAU/BU 000~111
RCTUA 000~031 B3CAU/BU 000~191
RCTUBA/BB 000~079 B5CAU/BU 000~335
RCTUC/D 000~239
RCTUE/F 000~335
Port Hold Time Port Hold Time Port Hold Time Port Hold Time
SELECT = Station Logical Port Number
Enter the port number that needs a Ring Transfer Recall
Time assigned.
To add a port range, enter XXX✱XXX (low port ✱ high port).
HOLD TIME = Port Number
Enter the Ring Transfer Recall Time (three
digits, in seconds)
Enter 011~999 for 11 to 999 seconds.