Toshiba DK424 Telephone User Manual


 
System & Station
Program 20 Computer and Data Interface Unit Configuration
Strata DK Programming 5/00 3-59
System & Station
Notes
RPCIs and PDIUs cannot be connected to PDKU1 circuit 8, but can be connected to all eight
PDKU2 circuits. RPCIs and PDIUs that support data switching cannot be connected to PDKU
in all slots. See the Strata DK I&M Manual, DK424 Chapter 4 DK424 Configuration, Tables
4-4 and 4-5, Chapter 6 DK424i Configuration to identify which slots can support RPCIs and
DIUs and Chapter 12 Peripheral Installation for additional hardware information. DK40i
slots 17 and 18 do not support data switching.
If a PC is connected to the RPCI or PDIU, set the communication mode escape sequences in
the PC communication software Modem Initialization character sequence. This ensures the
escape sequence is restored in case the RPCI Telephone or PDIU is unplugged temporarily.
RPCI and PDIU-DS units that mostly do data switching, can be connected to ports associated
with PDKU1 circuits 1~7 only. All PDKU2 circuits, 1~8, support RPCIs and PDIUs. RDSU
digital circuits 5~8 support RPCI and PDIUs.
Each PDIU-DS requires a separate digital port.
If a PDIU-DS (Stand-alone Data Interface Unit) is connected to a modem, refer to Modem
Setup Recommendations in the PC/Data Communication section of Chapter 12 Peripheral
Installation of the Strata DK I&M Manual.
Typical LED Settings for Program 20
RCPI-DI/PDIU-DI Connected to a terminal or personal computerLEDs 01, 02, 05, and 17 On;
all other LEDs Off.
PDIU-DS Connected to a Printer: LEDs 01, 04, and 17 On; all other LEDs Off.
PDIU-DS Connected to a Modem: LEDs 01, 02, 03, 04, and 17 On; all other LEDs Off.
LEDs 17~20: Data Security Groups
Data security groups can be set to block data calls between RPCI/DIUs. RPCI/DIUs can only
make data calls to RPCI/DIUs in the same security group. LEDs 17~20 assign the RPCI/DIU to
the appropriate security group: light LED 17 for Group 1; LED 18, for Group 3; LED 19, for
Group 2; and LED 20, for Group 4. If an RPCI-DI is used in the Application Program Interface
(TAPI) mode only, and not the Data Switching mode, this option is not applicable.
LEDs 12~16
Not used at this time.
LED 11: RPCI-DI DNIS to PC Option
DNIS Number or NAME tag information that is sent to a telephone can be sent, or blocked, from
the telephones RPCI-DI, RS-232 output. If DNIS information should be sent from the
Telephones RPCI-DI to the Personal Computer to which it is connected, turn LED 11 On; if this
information should not be sent to the PC, turn LED 11 Off.
LED 10: RPCI-DI Caller ID and ANI to PC Option
Caller ID and ANI information that is sent to a telephone can be sent, or blocked, from the
telephones RPCI-DI, RS-232 output. If Caller ID and ANI information should be sent from the
RPCI-DI to the Personal Computer to which it is connected, turn LED 10 On; if this information
should not be sent to the PC, turn LED 10 Off. This option does not apply to PDIUs because they
can not send ANI, Caller ID, or DNIS numbers.