Panasonic KX-TD1232E Telephone User Manual


 
Specifications
6-20 Appendix
General Description
Item Description
System Capacity
Power Supplies
Dialling
SMDR
(Station Message
Detail Recording)
Basic Expansion System
Connection
KX-TD816
Outside lines 0 12
Wired extension 8 16
Wireless extension* 016
(Extension lines with XDP/SXDP 16 32 )
KX-TD1232
Outside lines 0 38 38
Wired extension 16 32 64
Wireless extension* 064 64
(Extension lines with XDP/SXDP 32 64 128 )
*This is the maximum number of DECT portable stations that you can
register.
Primary 230 VAC, 50 Hz
Secondary Station Supply Volt: 30V
Circuit Volt: ± 5V, ± 15V
Power Failure Memory backup duration: seven years with a
factory-provided lithium battery
3 outside lines max. for KX-TD816 and 6 outside
lines max. for KX-TD1232 automatically assigned
to specic single line telephone (Power Failure
Transfer)
System operation for about three hours using
recommended batteries (consisting of two 12
VDC car batteries).
Outward/Internal Dial Pulse (DP) 10 pps, Tone (DTMF) Dialling
Mode Conversion DP-DTMF, DTMF-DP
Interface EIA (RS-232C)
Output Equipment Printer
Detail Recording Date, Time, Extension Number, Outside Line
Number, Dialled Number, Ring Duration, Call
Duration, Account Code, Department Code,
Charge Fee
Characteristics
Item Description
Maximum Number of Station
Instruments per Line
Ring Voltage
Environmental Requirements
1 or 2 by Parallel or eXtra Device Port Connection
65 Vrms at 32 Hz depending on the ringing load
0 40 °C, 10 90% relative humidity