Panasonic Advanced Hybrid System Telephone User Manual


 
2-34 Installation
2.23 System Data Clear
When the system does not operate properly after restarting, you can clear the programming
data stored in the system. The system will restart with the default settings.
First, try system program [999] “System Data Clear” by following step 4 in 2.21, “Starting
the System for the First Time”. If the system still does not operate properly, please follow
the procedure below.
1. Slide the System Clear Switch to the “CLEAR” position.
2. Press the Reset Button.
3. Return the System Clear Switch to the “NORMAL” position before the power indicator
stops flashing.
(The power indicator will flash for about 10 seconds.)
CAUTION • Before touching the System Clear Switch and Reset Button, put on a
grounding strap.
After pressing the Reset Button, return the System Clear Switch to the “NORMAL”
position in step 3 before the power indicator stops flashing. Otherwise, the system will
not clear.
Feature Reference
Section 3, Features
System Data Default Set
!
!
CLEAR/NORMAL
System Clear Switch
Reset Button
PSQX1708ZA-03E.QX 99.10.15 5:47 PM Page 34