Panasonic Advanced Hybrid System Telephone User Manual


 
( 5 of 6 )
NEW
P
rogramming Steps
( with reference to the KX-T30810 / 61610 )
Step Program Title Feature Description Default
211 No Dial Disconnection Call disconnects if 1
st
Digit is not dialled
within 20 seconds of seizing a CO Line
Enable
( disconnect )
212 CO Line Duration Limit Sets maximum CO call time (Enabled Prog 613) 10 mins
213 Bell Off Detection Sets the wait time between bell signals from CO line 3 secs
301 Call Barring – System Speed Dial
Boundary Class
Assigns the call barring class for System Speed Dial
Numbers
Class 1
309 Emergency Dial Number Set Stored ‘Emergency’ telephone numbers override the
following : ‘COS Level’ / ‘Account Code Modes’ /
‘Electronic Extension Lock’
Locations
01 : 999 02 : 112
03 ~ 05 : Not stored
310 Account Codes Assigns Account Codes for ‘Verify - All’ mode 01 ~ 24 : Not stored
i.e. 01 : 1234
311 Automatic Pause Insertion Codes 40 codes can be assigned as Pause Codes.
Pause [ duration prog. step 417 ] is inserted after the
code
01 ~ 40 : Not Stored
i.e. 01 : 1234567
312 Call Barring – Extension Lock COS level applied to Locked Extensions
Options : COS Levels 2 / 3 / 4 / 5 / Disabled
Disabled
400 CO Line Connected Assignment Defines connected CO’s CO 1 ~ 6 : Connected
402 Pulse Speed Selection Sets CO Line ‘Pulse Speed’
Options : 10 / 20 pps
10 pps
404 CO Line Group Assignment Trunk Group assignment of CO’s CO 1 : Trunk Group 1
through to
CO 6 : Trunk Group 6
414
to
416
Outside Line Mode
( Day / Night / Lunch )
NORMAL : Follows programming steps 408 ~ 410
DIL : Assigns one ext. to receive I/C CO call
(must be used if Call FWD is required)
DISA1 : The caller will hear a Tone or OGM
DISA2 : The caller will hear two different OGM
UCD : Call will be rec’d via UCD function
NORMAL
417 Pause Time Assigns the Host PBX pause time 1.5 secs
421 CPC Detection for Outgoing Calls Enables CPC detection during an outside call.
If CPC is detected, the system disconnects the line
( disconnection time Program Step 420 )
Disable
423 CO Line Ringing Pattern Selection Incoming CO Line ringing pattern
Options : Single / Double / Triple Ring
Double
424 Reverse (Polarity) Check Detects CO Line reversal Disabled
500 DISA Incoming Dialling Mode
Selection - Auto Attendant
Without AA System accepts : Ext. / Access No.
With AA System accepts : Ext. / Access / AA No.
Without AA
501 DISA Built-in Auto Attendant Assigns Auto Attendant numbers ‘0 ~ 9’
to extension jacks
0 ~ 9 : Not stored
i.e. 0 : Jack 01
502 OGM Mode Selection
( KX-TA 62491 required )
Mode 1 ~ 6 DISA or UCD functions can be used
to receive IC calls
Mode 1
503 FAX Connection
( KX-TA 62491 required )
Assigns an extension to receive FAX calls
when CNG is detected
All Jacks : Disabled
504 DISA Delayed Answer Time Assigns delay in DISA answering a call
Options : 0 / 3 / 6 / 12 secs
3 secs
505 DISA Waiting Time after OGM Selects time the system waits for DTMF
or CNG tone after OGM played
Options : 0 / 5 / 10 / 15 secs
5 secs
506 DISA Busy Mode Sets DISA response to a dialled busy extensions
Options : Call waiting / Disconnect / play OGM 2
Disconnect
507 DISA Intercept Mode
Disconnect / Intercept
Sets DISA response to unanswered calls
Options : Disconnect / Intercept
Intercept
508 DISA Ring Time before Intercept Sets DISA Intercept time for unanswered calls
Options : 10 / 20 / 30 / 40 / 60 / 120secs
20 secs
509 DISA Ring time After Intercept Sets the ring time at the Intercept destination
Options : 10 / 20 / 30 / 40 / 60 / 120secs
20 secs
510 DISA No Dial Mode Selects action taken by DISA if no response is received
after OGM ( e.g. DTMF or CNG )
Options : Intercept / Disconnect
DISA1 : Intercept
DISA2 : Intercept
513 Cyclic Tone Detection
( OGM option KX-TA62491 required )
Sets the number of times Cyclic Tone has to be detected
before the system regards the call as complete
Options : Disable ( does not detect ) / 2 / 3 / 4 times
4 times