Panasonic Advanced Hybrid System Telephone User Manual


 
System Programming 4-71
4.2 System Programming [605]
Selects the account code input mode, Option, Forced, Verify–All or Verify–Toll (Call
Barring), for each extension port. This feature displays the account code of the called or
calling party on the SMDR.
Option: The user can enter any account code, if needed.
Forced: The user must always enter an account code. The code can be any number.
Verify–All: The user must always enter an assigned account code in program
[310] “Account Codes” to make an outside call.
Verify–Toll (Call Barring): The user can enter an assigned account code in program
[310] to override call barring. The call barring COS
numbers 3 through 5 will be changed temporarily to the
COS number 2. (The COS numbers 1 and 2 will not be
changed.)
* Extension port number: 01 through 24 / (All extension ports)
Default All extension ports – Option
Feature References
Section 3, Features
Account Code Entry, Call Barring Override by Account Codes
5
0
6
[605] Account Code Entry Mode
NEXT
END
extension port no.*
SELECT
SELECT
(Option/Forced/
Verify-All/Verify-Toll)
(01
···
24/ )
NEXT
PREV
or
To continue
STORE
To continue