Panasonic Advanced Hybrid System Telephone User Manual


 
4-68 System Programming
[524]-[526] 4.2 System Programming
Assigns the length of time for the Intercept Routing – No Answer feature ([524] “UCD
Intercept Mode”, Intercept). When the time expires, the system starts to redirect the call to
the programmed extension(s).
Default 20 seconds
Feature References
Section 3, Features
Intercept Routing, Uniform Call Distribution (UCD)
[525] UCD Ringing Time before Intercept*
1
2
5
NEXT
5
STORE
END
SELECT
(10/20/30/
40/60/120 sec)
Assigns the length of time to call the extension(s) where a call is redirected by the Intercept
Routing – No Answer feature ([524] “UCD Intercept Mode”, Intercept) after the time
programmed in [525] “UCD Ringing Time before Intercept” expires.
Default 20 seconds
Feature References
Section 3, Features
Intercept Routing, Uniform Call Distribution (UCD)
[526] UCD Ringing Time after Intercept*
1
2
5
NEXT
6
STORE
END
SELECT
(10/20/30/
40/60/120 sec)
Selects the operation when all extensions in the UCD group do not answer an outside call
via the UCD feature within the length of time programmed in [525] “UCD Ringing Time
before Intercept”. Intercept or Disconnect is available.
Intercept: The call is redirected depending on programs [408]-[410] “Flexible Ringing
Assignment–Day/Night/Lunch” (Intercept Routing – No Answer feature).
Disconnect: The call is disconnected.
Default Intercept
Feature References
Section 3, Features
Intercept Routing, Uniform Call Distribution (UCD)
[524] UCD Intercept Mode*
1
2
5
NEXT
4
STORE
END
SELECT
(Intercept/
Disconnect)
*
1
: Required only when the optional OGM/FAX Detection
Card is installed.