Honeywell 9900 PDAs & Smartphones User Manual


 
5 - 4 Rev A
8/6/08
Dolphin® Power Tools User’s Guide
SuffixID Specifies the symbology identifier sent
after the decoded/received data.
0 0=No symbology identifier is
sent.
1=The Code ID is sent.
2=The AIM ID is sent.
3=The SymModifier is sent.
SoundConnect Enables and disables
The sound that ScanWedge makes
when starting up, shutting down, or
restarting.
The audio notification when an IrDA
session is established and closed
and the serial port is opened and
closed.
1 0=Disabled
1=Enabled
Note: Audio notifications for
errors can’t be disabled.
MessageConnect
This key applies only
to the IrDA and serial
ports.
Enable and disables a notification
message when an IrDA session is
established and closed and the serial
port is opened and closed.
0 0=Disabled
1=Enabled
Accept EZConfig
This key applies only
to the decoder.
Enables and disables ScanWedge’s
compatibility with EZConfig Client when
decoding bar codes.
1 0=Disabled; ScanWedge
processes EZConfig
barcodes as it would any
other barcode.
1=Enabled; ScanWedge
recognizes EZConfig
barcodes and passes them
on to the EZConfig Client for
further processing.
Settings Section
The Settings section determines how ScanWedge interprets data from the decoder, serial port, and IrDA
interface.
0 = Disable 1 = Enable
Settings Section
Key
Description Default
Value
Available Values