Nortel Networks BM450 Telephone User Manual


 
32 Chapter 3 Hardware Troubleshooting
NN40160-700NN40160-700
3 Check that the correct feature for digital sets is included in your installed keycode.
4 Verify that the ATA2 is connected to a digital station port.
5 Allow sufficient startup time (30–60 sec).
6 Plug an analog device into the phone port of the ATA2 and check for a dial-tone.
7 In Element Manager, verify that the ATA 2 is correctly configured:
a Select Configuration > Telephony > Sets > All DNs.
b Select the appropriate DN from the list and click the ATA settings tab.
The options for the Device Type are Modem or Telephone.
To determine why there is no dial tone at the ATA2
1 If you hear no dial tone, replace a single-line telephone for the data communication device.
2 If you hear no dial tone at the ATA2 unit:
a Disconnect the line side of the ATA2. Connect a digital telephone to the ATA2 port.
b Check that the connection from the ATA2 to the BCM450 hardware works correctly.
To check the ATA2 wiring
1 Use an analog phone to test the ATA2.
2 Check the following connections:
a ATA 2 to the terminal
The resistance must be 200 ohms or less for data applications and 1300 ohms or less for
voice applications.
b BCM450 hardware to the ATA2
The wiring must be equivalent to 800 m of 0.5 mm wire (2600 ft. of 24-AWG) or less. Do
not use bridge taps and loading coils between the BCM450 hardware and ATA2.
Reset to factory settings
This section describes how to reset the BCM450 system to the factory settings or a stable working
condition using the reset switch (see the figure Reset switch location on page 33). When the
BCM450 is in this condition, you can make further modifications.