Alcatel-Lucent 4610 IV Answering Machine User Manual


 
93 93
Playback options:
The statistics history starts
either 7 days before or with
the point of counter -reset:
0
9
#
7
Step back in history by
one day
step forward in history
by one day
go to end (announceĆ
ment of current free
voice memory)
step forward in history
by one hour
System Utilisation - Statistics (continue)
To have an overview on the current system load, each full hour a check
of free voice memory is done and the total seizure duration is counted:
- Free memory: free voice memory in the system measured in
minutes within the specific hour.
- Seizure duration: Mean value of seizure duration of the access
lines to the Alcatel 4610 IV as percentage of the maximum posĆ
sible seizure within the specific hour.
Example:
- Seizure duration for access line 1: 24 minutes
- Seizure duration for access line 2: 12 minutes
Total seizure duration is 36 minutes of the maximum possible
duration of 120 minutes (60 minutes per access): 30% seizure
duration.
The information on the load situation is available for the last week.
Technical details:
Seizure duration includes notification calls, message waiting LED
update. Free memory is stored in 'minutes' and the seizure duraĆ
tion in 'percent'. The statistics history starts at the last system or
counter reset (whatever was later). The maximum period covered
by the history is 168 (7x24) hours.
Note: The first hour may be incomplete.