Operational Features
41-001160-01, Rev 00, Release 2.3 5-221
Configuring Operational Features
Configuring Park/Pickup Key Using Configuration Files
In the configuration files, you configure Park/Pickup using the key parameters.
You must specify the "softkeyN value", "prgkeyN value", “topsoftkeyN value“, or
“expmodX keyN value”. The following examples show Park/Pickup
configurations using specific servers.
Model 57i/57i CT and 9480i/9480i CT Examples
*When you configure a softkey as "Park", you must configure the state of the softkey as
"connected".
**When you configure a softkey as "Pickup", you can configure the state of the softkey as "idle,
outgoing", or just "idle", or just "outgoing".
Server Park Configuration Pickup Configuration
Asterisk softkeyN type: park
softkeyN label: parkCall
softkeyN value: asterisk;70
softkeyN line: 1
softkeyN states: connected*
softkeyN type: pickup
softkeyN label: pickupCall
softkeyN value: asterisk;70
softkeyN line: 1
softkeyN states: idle, outgoing**
Sylantro softkeyN type: park
softkeyN label: parkCall
softkeyN value: sylantro;*98
softkeyN line: 1
softkeyN states: connected*
softkeyN type: pickup
softkeyN label: pickupCall
softkeyN value: sylantro;*99
softkeyN line: 1
softkeyN states: idle, outgoing**
BroadWorks softkeyN type: park
softkeyN label: parkCall
softkeyN value: broadworks;*68
softkeyN line: 1
softkeyN states: connected*
softkeyN type: pickup
softkeyN label: pickupCall
softkeyN value: broadworks;*88
softkeyN line: 1
softkeyN states: idle, outgoing**
ININ PBX softkeyN type: park
softkeyN label: parkCall
softkeyN value: inin;callpark
softkeyN line: 1
softkeyN states: connected*
softkeyN type: pickup
softkeyN label: pickupCall
softkeyN value: inin;pickup
softkeyN line: 1
softkeyN states: idle, outgoing**