Avaya 03-300686 Telephone User Manual


 
1152B Mid-Span Power Distribution Units
Issue 3 January 2008 125
- Dropped or the housing has been damaged
- Exhibits a distinct change in performance
- Operates abnormally when following the operating instructions
Using the 1152B PDUs
The 1152B PDUs are used to power the 46xx series and 96xx series of IP telephones in
addition to providing 10/100 megabits per second Ethernet connection.
Generation 1 Avaya IP telephones can receive power from the 1152B using an in-line adapter.
This adapter provides the resistive signature so that the 1152B allows power to flow to the
telephone. The generation 2 telephones do not need an adapter.
The 1152B PDU has 10/100 Base-T ports, each of which can supply a minimum of 15.4 watts
using the internal power supply and operates on a 100-240 volts AC, 60/50 hertz power source.
The 1152B PDU is 1U high and fits in most standard 19-inch racks. It can also be mounted on a
shelf. Refer to the user’s guide that comes with the unit for complete installation instructions.
Connecting the 1152B PDU cables
All of the ports on the front of the 1152B PDU are configured as data route-through ports for all
data wires (pins 1, 2, 3 and 6).
Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including
all 8 wires (4 pairs) as shown in Connecting cables to telephones and other end devices
on
page 126.
h2cm1152 LAO 122006
1 2 3 4 5 6
Data &
Power
Data
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
communication
1152B1 Power
Distribution Unit
AC
48Vdc
Console
PWR