Avaya 03-300686 Telephone User Manual


 
1152B Mid-Span Power Distribution Units
Issue 3 January 2008 123
To connect telephones and other end devices to the 1152A1 PDU:
1. Connect an Ethernet cable to the telephone using an external splitter or directly (if the
device is Power over LAN Enabled).
2. Connect the opposite end of the same cable to the RJ45 wall outlet.
3. On the front panel of the 1152A1 PDU, monitor the response of the corresponding port LED.
If it lights up GREEN, the unit has identified your telephone as a Power over LAN
1152B Mid-Span Power Distribution Units
The Avaya 1152B Mid-Span Power Distribution Units are Ethernet power supplies that provide
power to up to 48 46xx-series or 96xx IP telephones or wireless LAN (WLAN) access points.
The 1152B PDUs are designed to deliver power in addition to data communication over an
Ethernet network. The 1152B PDUs eliminate the need to connect each Ethernet Data Terminal,
such as an IP Telephone set, to an AC power outlet in addition to the data port. The system also
removes the need for power cables, local AC wall adapters and the use of a dedicated UPS for
each IP telephone. Some models support SNMP remote management via a separate physical
RJ45 input port.
These units are used with a standard 10/100BaseTx Ethernet network infrastructure using
standard TIA/EIA-568 Category 5, 5e, or 6 100-Ohm Unshielded Twisted Pair (UTP) cable. The
1152B meets the current requirements of the IEEE802.3af-2003 standard for resistive detection.
The units are as follows:
Table 21: 1152B Midspan Power Distribution Units
Avaya Model
Number
Number of
Ports
SNMP Summary
1152B48S 48 Yes 48-port, AC Input, 48Vdc Output with SNMP
1152B24S 24 Yes 24-port, AC Input, 48Vdc Output with SNMP
1152B06 6 No 6-port, AC Input, 48Vdc Output
1152B06S 6 No 6-port, AC Input, 48Vdc Output with SNMP