Panasonic CPC-EX Telephone User Manual


 
Chapter 4. Trunks and Lines
Section 300-Installation
4-12 DBS Manual - Revised April 2000 DBS-2.3/9.2-300
Table 4-7. T1 Hardware requirements for double-cabinet systems
The T1 trunk card must be installed in the “EC/TRK” slot.
The installer
must
provide a Channel Service Unit (CSU) that complies
with FCC Part 15 and Part 68. The CSU is installed between the DBS and
the public network. The CSU provides alarm, diagnostic, and monitoring
functions, as well as network protection.
The CSU must be compatible with the framing format (SF or ESF) that is
provided by the public network.
Maximums
One T1 card can be installed per cabinet.
The number of T1 cards that can be installed in double-cabinet systems
depends on the sizes of the connected systems. Table 4-12 on page 4-15
shows T1 maximums for double-cabinet systems.
Note:
The DBS 72 + DBS 40 combination does not support T1.
T1
Location
CPC-B V4
(VB-43411)
(See Note
1.)
SCC-B
(VB-
43421)
(See Notes
2 and 3.)
T1 Trunk
Card
(VB-
43561)
T1 MDF
Card
(VB-
43562)
Sync
Card
(VB-
43563)
T1 Cable
(VB-
43564)
Cable Kit
(VB-43110)
(See Note
4.)
T1 in the
Master
1 1 1110 1
T1 in the
Slave
1 11111 1
T1 in both
Master
and
Slave
1 1221
11
Notes:
1. Version 1.3 of the Bus Processor Unit (BPU) chip is required for T1.
2. An MFR card is required for DID/DNIS if DTMF signaling is used. If DID/DNIS is provided through DP sig-
naling, an MFR card is not required.
3. SCC-B with ROM 1.3 or later is required if the central office does not provide T1 dial tone.
4. Version 1.2 of the Cable Kit is required for T1.