Section 300-Installation Chapter 7. Specifications
DBS-2.3/9.2-300 DBS Manual - Revised April 2000 7-3
Electrical Characteristics
Table 7-1. Input power
Table 7-2. Power consumption and heat generation
Table 7-3. Battery backup capacity
Equipment Power Requirements
All DBS cabinets 120V AC ± 10 % 60 Hz
DBS key phones 3 watts maximum (powered from the DBS)
System
Status
DBS 40
DBS 72
DBS 96
DBS 40 +
DBS 40
DBS 72 +
DBS 40
DBS 72 +
DBS 72
DBS 96 +
DBS 40
DBS 96 +
DBS 72
DBS 96 +
DBS 96
Power Consumption (in Watts)
With no traffic 170 250 320 340 420 500 490 570 640
With max. traffic 216 324 444 432 540 648 660 768 888
Heat Generation (Btu per hour)
With no traffic 580 853 1092 1160 1433 1706 1672 1945 2184
With max. traffic 737 1106 1515 1474 1843 2212 2253 2621 3031
System Battery Pack Capacity (with maximum traffic)
DBS 40 VB-43130 40 minutes
DBS 72 VB-43130 40 minutes
DBS 96 VB-43130 30 minutes