Section 300-Installation Chapter 6. Double-Cabinet Systems
DBS-2.3/9.2-300 DBS Manual - Revised April 2000 6-3
Guidelines
Two DBS cabinets can be connected to increase line size. The maximum
line size consists of two DBS 96 cabinets, which provide 192 ports.
CPC-B and SCC-B are required for two-cabinet systems.
If ground start or DID trunks are used in both cabinets, separate -48V
supplies must be supplied for each cabinet. If AECs are used in both
cabinets, separate SLT ringer boxes must be supplied for each cabinet.
The following table shows the acceptable combinations of system types
Table 6-1. Trunk and extension port maximums for double-cabinet systems
Figures 6-1 through 6-6 shows slot usage for two-cabinet combinations.
System
Combinations Trunk Extension Expansion Ports
Master Slave Ports Ports (Trunk lines or
extensions)
DBS 40 DBS 40 16 48 8 (See Note 1.)
DBS 72 DBS 40 24 72 0 (See Note 2.)
DBS 72 DBS 72 32 96 8 (See Note 1.)
DBS 96 DBS 40 32 88 16
DBS 96 DBS 72 40 112 16
DBS 96 DBS 96 48 128 16
Notes:
1. The slave cabinet must be used for expansion ports.
2. When a DBS72 and DBS40 are connected, expansion ports cannot be
used.