Panasonic CPC-EX Telephone User Manual


 
Section 300-Installation Chapter 4. Trunks and Lines
DBS-2.3/9.2-300 DBS Manual - Revised April 2000 4-11
Connect the test set across the tip and ring of the trunk to be tested. With
the test set in the “monitor” position, apply ground to the ring side of the
trunk.
If you hear dial tone, the polarity of the trunk is okay, and you can switch
the test set to the “talk” mode to test the voice path.
If you do not hear dial tone, ground the tip side of the trunk. If you
receive dial tone when grounding the tip side, polarity is reversed.
T1 Interface
Guidelines
Read the following guidelines before beginning T1 installation. Installation
instructions begin on page 4-21.
Hardware Requirements
The T1 requires the following DBS hardware.
Table 4-6. T1 Hardware requirements for single-cabinet systems
CPC-B 4.0 or
Higher
(VB-43411)
SCC-B
(VB-43421)
T1 Trunk Card
(VB-43561)
T1 MDF Card
(VB-43562)
Sync Unit
(VB-43563)
1
(See Note 1.)
1
(See Notes 2 and 3.)
111
Notes:
1. Version 1.3 or higher of the Bus Processor Unit (BPU) chip is required for T1.
2. An MFR card is required for DID/DNIS if DTMF signaling is used. If DID/DNIS is provided through
DP signaling, an MFR card is not required.
3. SCC-B with ROM 1.3 or higher is required if the central office does not provide T1 dial tone.