Meridian Audio M3900 Telephone User Manual


 
Appendix A: Flash Download procedure Page 129 of 174
M3900 Series Meridian Digital Telephones Description, Installation and Administration
LD 97 Configure the system-wide Flash Download parameters.
Prompt Response Description
REQ CHG
PRT
Change Flash Download parameters.
Print Flash Download parameters.
TYPE FDL Flash Download for M3900 sets.
FDTP t
<CR>
Enter M3900 set type selected for Flash Download
3902 = M3902
3903 = M3903
3904 = M3904
3905 = M3905
ALL = All of the above
NONE = None of the above (default)
FDTM
(NO)
YES
Time interval restriction for Flash Download
Do not change time intervals (default).
Proceed to change time intervals.
Note 1: Flash Download is automatically paused one hour before
virtual midnight (see TODR in LD 17) to allow midnight routines to
run.
Note 2: This option is not applicable to reporting.
FDAY dn Enter the day and number of time intervals for the Flash
Download.
The FDAY prompt appears only if FDTM = YES.
Day is reprompted until you enter a <CR>
d = Day of the week (0-6 for Sunday to Saturday)
n = Number of time intervals (0-4)
To disallow download for the day, enter 0.
Note: If two or more intervals are specified, they must be
non-overlapping, non-consecutive, and increasing in order.
FINT sl Enter starting hour and length for a time interval.
Prompted n times if n>0.
s = starting hour (0-23)
l = length of interval in hours (1-24)
FTNR
(NO)
YES
TN range restriction option for Flash Download.
NO TN restriction (default)
Specify TN range.