System & Station
Program 60-1 – SMDR Data Output Options
3-144 Strata DK Programming 5/00
Program 60-1 – SMDR Data Output Options
Processor Type: DK14, DK40i, all RCTUs and BCUs
Program Type: System
Initialized Default: LED 01 Off
Program 60-1 Overview
Program 60-1 determines which information will be sent out the system SMDR port: System
Account codes or Caller ID and/or ANI telephone numbers.
Turn LED 01 On if received Caller ID and/or ANI information should be sent out the system
SMDR port.
Turn LED 01 Off if Account Code information should be sent out the system SMDR port.
Note LED 01 determines if received Caller ID and/or ANI information (LED 01 On) or data is
sent out the SMDR port. This data is output on the last 15-digit (right hand) field columns
of the SMDR print out.
✱ ✱ ✱ ✱ 6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
LED/
Button
X LED On LED Off
20
19
18
17
16
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
Caller ID, ANI and DNIS data will be sent from the
system SMDR port
Account code data will be sent from the system
SMDR port
Light the LED Buttons that are marked
with an X in the table below.
SELECT = 1