System & Station
Program 35 – Station Class of Service
3-100 Strata DK Programming 5/00
Program 35 – Station Class of Service
Processor Type: DK14, DK40i, all RCTUs and BCUs
Program Type: Station
Initialized Default: LED 01, 02, 04, 05, 16 are On, all other LEDs Off.
✱ ✱ ✱ ✱ 6SNU +ROG 6SNU +ROG 6SNU +ROG 6SNU +ROG
Processor Type Port Range
Maximum LCD Phones With
Personal Messages
Processor Type Port Range
Maximum LCD Phones With
Personal Messages
DK14 000~009 8 B1CU 000~055 32
DK40i 000~027 16 B2CAU/BU 000~111 96
RCTUA 000~031 16 B3CAU/BU 000~191 96
RCTUBA/BB 000~079 32 B5CAU/BU 000~335 96
RCTUC/D 000~239 96
RCTUE/F 000~335 96
Feature LED
Port
Busy Station Transfer
20
Busy Station Ringing
19
Automatic Hold
18
DKT 2000 Telephone
Continuous DTMF Tones Off
17
No CF/NA Handsfree or OCA
16
ISDN Immediate Dialing
15
Toll Restriction After Answer
14
Toll Restriction After Answer
13
Not used
12~09
ISDN Cause Code Display
08
Not used
07
Disable Hold Display
Scrolling (Release 3.2 and
higher)
06
LCD Personal Message
(10~19) Allowed
05
Message Waiting (RCV)
04
Message Waiting Lamp
Standard Telephones
03
LCD Type/32-On/12-Off
02
LCD Display
01
SELECT = Station Logical Port Number
Enter the port number(s) being defined.
To add a port range, enter XXX✱XXX
(low port ✱ high port).
LED = Select LEDs to light for the port
specified in the last step. Mark an “X” in the
table below for all LEDs which should be On.