2.3.1 PC Programming
Description
System programming settings can be accessed using a PC and the Panasonic KX-TE Maintenance
Console software as well as by using a proprietary telephone (PT) ( 2.3.2 PT Programming). System
programming and data upload/download can be performed either through on-site programming or remote
programming.
1. On-site Programming: Programming that is performed using an on-site PC connected directly to
the PBX.
2. Remote Programming: Programming that is performed using an off-site PC that connects to the
PBX via an outside (CO) line.
1. Connection Methods for On-site Programming
2. Connection Methods for Remote Programming
Method Description
Required
Hardware
Serial Interface
(RS-232C)
The PC is connected to the PBX via the Serial Interface (RS-
232C) port of the PBX.
USB The PC is connected to the PBX via the USB port of the PBX.
Method Description
Required
Hardware
Remote modem Call the PBX and have the call directed to the internal modem
using one of the following methods:
Direct Access: Using a modem, dial the telephone number to
connect to the internal modem. To use this feature, "MODEM"
must be selected as the distribution method for the desired
outside (CO) line port ( CO Line Mode—Day/Night/Lunch
[414-416]).
DISA: Using a telephone, dial the telephone number to reach
the DISA line ( 1.15.6 Direct Inward System Access (DISA)).
After hearing a DISA outgoing message (OGM), enter the
Remote Maintenance feature number to access the internal
modem. To use this feature, "DISA" must be selected as the
distribution method for the desired outside (CO) line port (
CO Line Mode—Day/Night/Lunch [414-416]).
Call Transfer: Using a telephone, call an extension user, such
as the operator, to request to be transferred to the internal
modem using the Remote Maintenance feature number (
1.11.1 Call Transfer).
User-supplied
modem