Settings 43
You need to know the remote switching and programming MSN/DDI
configured with the configuration program COMset.
If you call the PBX and enter the correct external password as described
here, you will hear the external acknowledgement tone. Now you use
the same programming digits as from the internal telephone (after the
password). Then you will hear the external acknowledgement tone
again.
If you wait too long with entering the code sequence or enter the wrong
code, you will hear the busy tone. Hang up the receiver and try again.
If you entered by mistake a relay not configured for remote switching,
you will hear an alternating high and low tone (negative acknowledge-
ment tone). You will be able to start again from this situation - after this
tone - unconditional.
Alarm functions:
If your PBX is equipped with a door/switching module
and an alarm input on the module is properly connected, you can also
use the alarm functions. Alarm functions are the activation of a siren and
alarm indicator light (via switching relay) and the repetitive alarm calls
to a a maximum of 4 alarm subscribers (internal and external). The
alarm subscribers will listen to an alarm announcement (COMpact
4410 USB and COMmander Basic only). This can be recorded by tel-
ephone (p. 47) or stored with the program COMtools Music on Hold
(p. 60) in the PBX.
The Alarm Procedure:
ț Alarm detection at the alarm input (contact closed longer than ½ a
second).
ț The configurable alarm delay time is running (0-99 seconds).
ț Non recurring start of the siren (for 1-99 seconds) and/or the alarm
indication light (for 1-99 minutes).
ț Simultaneously the first alarm call run starts (Alarm calls to the alarm
subscribers):
- Calling the first alarm subscriber for 60 seconds. Internal alarm
subscribers are called with a special ringer rhythm (ISDN tele-
phones: See manual of your telephone).
- After taking the receiver, you will hear an alarm announcement
stored in the PBX (COMpact 4410 USB and COMmander Basic
only; p. 47) again and again (in case of COMpact 2206 USB you
hear a signal tone instead). The called party must acknowledge the
alarm call within 60 seconds by sending the DTMF number
0
(p. 22).
- If the called party does not acknowledge the alarm call, the next
alarm subscriber will be called some seconds after finishing the
first call. And so on.....
ț If all alarm subscribers are called without receiving an acknowledge-
ment, the alarm run will be repeated after a configurable alarm wait-
ing period (0-99 seconds) has elapsed (you can configure 1-10
alarm runs).
ț The alarm will be terminated (including siren and alarm indication
light) as soon as one of the alarm subscriber acknowledges the
alarm. If the alarm input has been configured to „active once“, it is
deactivated afterwards. If the alarm input has been configured to
„active repetitive“, it is activated again and a new alarm can be trig-
gered.
Activate Alarm:
You can activate the alarm with an internal or an exter-
nal telephone. If the alarm input has been configured to „active once“, it
is deactivated automatically afterwards. If the alarm input should remain
active after being triggered, configure it to „active repetitive“. (The alarm
input is deactivated in the default factory settings.)
One of the security functions of the PBX is the emergency call
priority function activated by the configuration program COM-
set. This functions provides an exchange line at any circumstance for
an emergency call or an alarm call to an external number. If all
exchange lines are busy, an active call will be terminated in favour of
the emergency call. The numbers can be entered with the PC software
COMtools (p. 60) or by telephone (p. 35).
If you like to reach one single number from a telephone in a very simple
way, you can use the Automatic Dialling (p. 39).
If you like to listen into a room from internal or external telephones, you
can use the room monitoring (p. 40).
You like to use the Security Functions
☞
Activate Alarm via internal Telephone
b 7 O 691 #
Activate the alarm function for one single alarm
secret
password
or
692
Activate the alarm function for multiple alarms
or
690
Deactivate the alarm input
Activate Alarm via external Telephone
bM f 7Wf
Start external Programming
external
telephone
remote switching and
programming MSN/DDI
tone
(1 sec)
continue with
DTMF
external
password
external acknowledgement tone
(1 sec continuous tone)