Samsung NX-308 Telephone User Manual


 
STATION HUNT GROUPS
System programming allows for up to 20 station groups. Four ring patterns are
available for each group: SEQUENTIAL, DISTRIBUTE, CONDITION and
UNCONDITION. Each group may contain a maximum 8 stations, and a station
may be associated with only one group at a time. Group 500 is reserved for the
operator group, and is called by dialing "0". Each station group has its own recall
time for calls transferred to that group.
MMC 35 ASSIGN STATION GROUP
MMC 70 DIAL NUMBERING PLAN SGR: 500-519 (Station Group ID)
OPR: 0 (Operator ID)
STATION MESSAGE DETAIL RECORDING (SMDR)
The system provides records of calls made, received, and transferred. Each call
record provides the station number, outside line number, date, start time, duration
of call, digits dialed (maximum 18) and an account code if entered. If the MPD
card is installed in the system, the call cost is printed in the ACCOUNT column in
place of the account code. The SMDR format contains many options which allow
it to be customized for a company's individual needs. Print options include
incoming calls and authorization codes. See sample printout on Page 3-26.
MMC 80 IO PARAMETERS
MMC 81 SMDR OPTION
STATION TO STATION CALLING RESTRICTION
Stations can be prevented from calling other stations.
MMC 32 INTERCOM USE
SYSTEM DIRECTORY
Each station and outside line may have a directory name of up to twelve (12)
characters. This name will appear on keyset displays to provide additional
information about lines and stations.
MMC 14 STATION NAMES
MMC 44 TRUNK NAMES
SYSTEM HALT
This is used only when all processing must be stopped. This feature is accessed
from within the technician programming level, and the appropriate passcode is
necessary to enable a SYSTEM HALT.
MMC 94 HALT PROCESS
NX-SERIES HYBRID KEY SYSTEM FEATURES SECTION
3 - 13