NEC ND-70895 (E) Amplified Phone User Manual


 
CHAPTER 5 ND-70895 (E)
Page 72
Revision 1.0
OFFICE DATA DESIGN
Procedure for Setting Office Data for OAI Services
3.4 TCP/IP Address (Assignment from MAT)
3.4.1 Functional Outline
In an OAI system to be connected with the host computer via the Ethernet, this function allows use of
TCP/IP port with the self internet address (TCP/IP address) of the NEAX2400 IMX assigned from the
MAT.
Also, whether system message “4-R” (IOC card for the host computer is faulty) is to be output or not
when the connection with the host computer has been normally disconnected can be selected by switch
setting on the Interface Processor (IP).
3.4.2 Using Conditions
1. Due to the hardware limitation, only one physical TCP/IP port can be accommodated per system.
2. Basic Value of TCP/IP Address is “172.16.253.0”.
3. The TCP/IP addresses (A, B, C, D) that cannot be used by this function are as follows.
Classes A, B, and C can be used. Note that Host Number = 0 cannot be used. (Conditions [1] ~[3].
Classes D and E cannot be used. (Condition [4])
Class A: [1] 0 A 127 A, 0, 0, 0
Class B: [2] 128 A 191 A, B, 0, 0 (0 B 255)
Class C: [3] 192 A 223 A, B, C, 0 (0 B 255, 0 C 255)
Class D, E: [4] 244 A A, B, C, D (0 B 255, 0 C 255, 0 D 255)
4. System message “4-R” output can be stopped by switch setting on the System Data only when TCP
connection has been disconnected (Normal) (ERRK=01).
<
<
< < < <
< < < < < <
< < < < < < <