NEC ND-70895 (E) Amplified Phone User Manual


 
ND-70895 (E) CHAPTER 5
Page 67
Revision 1.0
OFFICE DATA DESIGN
Procedure for Setting Office Data for OAI Services
4. When an incoming call terminates from ISDN network, ISDN caller’s number information
(subscriber’s number and sub-address) is provided from the central office in the following format.
Subscriber number is maximum 33 digits, and the sub-address is maximum 20 digits, and they are
separated by the separator “*” (OBH).
3.2.3 Data Programming
1. Assignment
ASYD (System Data)
SYS1
INDEX 79
b6: 0 (OAI service is not available)
INDEX 241
b2: 1 (OAI Call Status Monitor Facility Notification is not in service)
2. Deletion
ASYD (System Data)
SYS1
INDEX 79
b6: 1 (OAI service is not available)
INDEX 241
b2: 0 (OAI Call Status Monitor Facility Notification is not in service)
ISDN Callers Number Information
1
n
54
D
C
1
D
C
2
D
C
n
D
C
n–1