INSTALLATION PROCEDURE
OAI Software Installation
3. OAI Software Installation
This section explains the installation procedure for adding the OAI software to the PBX in off-line operation.
For more detailed information of program install procedure before the OAI application software install, see
“Installation Manual”.
[Operation Procedure]
STEP 1: By using MEM_HDD command, save all data to the both HDDs.
STEP 2: Make the Standard Service Software FD link with the OAI Option Service Software FD, and install
it into the HDD.
When OAI system is used in the Fusion Network (OAI Terminal Anywhere), link the ACD Option Service
Software for “Agent Anywhere” with the above software FD and install it into all the nodes. (valid since the
PBX software R8)
STEP 3: Initialize the system (perform IPL, DM loading).
PROGRAM=“LOAD”
SYSTEM DATA=“OVERRIDE/LOAD”
Note:
When OAI system is used through the Fusion Network [valid since Series 7400 (Release 8) software], the
UAP must be booted up after the confirmation of the establishment of the Fusion Link.
STEP 4: Change system data written in DM.
ASYD SYS1
INDEX31 - b0~b3: CM mounting capacity
Normally assign “04”.
Note 1 Note 2 Note 3
INDEX79 - b6=0 (OAI service is in service)
Note 1
INDEX207 - b0 (IP in system0), b1 (IP in system1)
Assign “1” to the corresponding bit for the IP accommodation.
INDEX241- b2=1 (Call Processing Event Notification)
Note 1
INDEX241- b3=1 (Details of SCF Error Notification)
Note 1
Note 1:
When OAI system is used in the Fusion Network, this data setting is necessary at the all nodes.
Note 2:
Reset the system after changing this data from 02H (normally assigned data value for the system without
OAI service) to 04H.
STEP 5: Assign the system data written in NDM.
This data below are necessary when OAI system is used through the Fusion Network.
ASYDN SYS1
INDEX514- NDM usage
INDEX533- FPC of the node that provides VNDM
(Normally, assign the FPC of the node that has the IP)
Note 3:
Assign “OG” for Series 7400 (Release 8) and later software.