NEC ND-70895 (E) Amplified Phone User Manual


 
CHAPTER 5 ND-70895 (E)
Page 70
Revision 1.0
OFFICE DATA DESIGN
Procedure for Setting Office Data for OAI Services
2. This service cannot be used simultaneously with other MW control services (VMM/MCI: Message
Center Interface/Message Waiting from Station, ATTCON and MAT).
3. The conditions for the telephone that controls MW are as follows.
MW can be serviced only on a telephone equipped with MW lamp function.
On a single-line telephone and/or D
term
, MW lamp display position is fixed.
On a single-line telephone, MW lamp flashing cannot be controlled (ON/OFF only).
MW lamp on/off/flashing, and LCD display can be controlled on a D
term
. (MW indication is
available only on a D
term
equipped with the indicator.)
•D
term
can control only lamp flashing (LCD display cannot be controlled).
4. In the case of MW service by SSFR (Confirm-type <Computer NEAX> Performer facility), the
same kinds of display (MW, VMS) as those of MCI (Message Center Interface) are possible.
5. In the case of deletion of all the station data and all the type data, only the same data as those of
MCI are deleted. MW service information for stations from the OAI Terminal Control Facility
(TCF) are not deleted.
6. In the case of MW service by SSFR, lamp on/flashing/off is immediately indicated at the time of
one station control. In the case of deletion of all the station data and all the type data, a delay time
of maximum 196 seconds generates until the status of the terminal changes actually.
7. The system configuration for implementing this service is as illustrated below.
Terminal NEAX2400 IMX
DLC
(D
term
)
Single-Line
Telephone
with MWL
TSW
LC
CPU IP
Appli-
cation
Program
Computer
SSFR
OAI
(AP)