Nortel Networks NN43001-504 Telephone User Manual


 
Configuration 153
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note: If using Windows 2000, Service Pack 2 must be installed
to enable the use of HyperTerminal™.
3
Reset the system.
The following appears on the terminal display:
04830130
4
Type the following command using the terminal or PC keyboard:
0255CC [CTRL M] [CTRL J]
The command does not display on the screen as it is typed.
The Login prompt appears. If an error is made when entering the
command string, the message Ill Formed Packet appears. It
appears as a series of numbers followed by some form of the typed
command. If this occurs, repeat Step 3 and Step 4.
5
Enter the default logon name and the default password:admin
admin
admin
admin
Note: The logon name and password are case-sensitive.
The NetLink OAI System screen appears. This screen, the
main menu screen of the Administration Console, displays the
factory-default name of the WLAN Application Gateway 2246 to
which the serial port is connected
—End—
Next, configure the WLAN Application Gateway (including IP address) by
following the steps in the "Task summary list" (page 154).
Configuration
The NetLink OAI System screen is the main menu of the Administration
Console. Use this screen to configure the WLAN Application Gateway 2246.
Nortel Communication Server 1000
WLAN IP Telephony Installation and Commissioning
NN43001-504 01.02 Standard
Release 5.0 15 June 2007
Copyright © 2004-2007, Nortel Networks
.