Linksys SPA942 Telephone User Manual


 
Linksys SPA9x2 Phone Administration Guide Cisco Confidential--First Draft179
SPA932 Status
SPA9x2 Phone Field Reference
General
For more information, see ”Setting Up the SPA932 Sidecar” section on page 114.
Unit 2
See the description for Unit 1 above. Enter a strings that define the extension and other
parameters associated with each lighted button on the second SPA932 unit. Keywords and
values are case-sensitive. The configuration script is described in ”Unit/Key Configuration
Scripts” section on page 118.
SPA932 Status
This page provides two tabs to display the status of up to two SPA932 units that are supported
by a single SPA962:
Parameter
Description
Subscribe Expires Specifies how long the subscription remains valid. After the
specified period of time, elapses, the SPA932 initiates a new
subscription.
Defaults to 1800.
Subscribe Retry Interval Specifies the length of time to wait to try again if subscription
fails.
Unit 1 Enable Enables or disables the first SPA932 unit (each SPA962 can
have up to two SPA932s attached).
Subscribe Delay Length of delay before attempting to subscribe.
Defaults to 1.
Unit 2 Enable Enables or disables the second SPA932 unit (each SPA962 can
have up to two SPA932s attached).
Server Type Selects the type of server used (SPA9000, Broadsoft, or
Askterisk).
Test Mode Enable Enables or disables test mode. When test mode is enabled, the
LEDs are turned on when keys are pressed, going from off to
green to red, and back to off. In test mode, when all the
buttons on the sidecar are returned to off, all the keys become
amber. The SPA962 must be rebooted after the test is
completed.
Call Pickup Code The star code used for picking up a ringing call.
Defaults to *98.
Unit 1 Key 1-32 Enter a strings that define the extension and other parameters
associated with each lighted button on the first SPA932 unit.
Keywords and values are case-sensitive. The configuration
script is described in
”Unit/Key Configuration Scripts”
section on page 118.
.