Linksys SPA9x2 Phone Administration Guide Cisco Confidential--First Draft145
Regional Tab
SPA9x2 Phone Field Reference
Control Timer Values (sec)
Vertical Service Activation Codes
The following Vertical Service Activation Codes are automatically appended to the dial-plan.
Parameter
Description
Reorder Delay Delay after far end hangs up before reorder tone is
played. 0 = plays immediately, inf = never plays. Range:
0–255 seconds.
Defaults to 255.
Call Back Expires Expiration time in seconds of a call back activation.
Range: 0–65535 seconds.
Defaults to 1800.
Call Back Retry Intvl Call back retry interval in seconds. Range: 0–255
seconds.
Defaults to 30.
Call Back Delay Delay after receiving the first SIP 18x response before
declaring the remote end is ringing. If a busy response is
received during this time, the SPA9x2 still considers the
call as failed and keeps on retrying.
Defaults to 0.5.
Interdigit Long Timer Long timeout between entering digits when dialing. The
interdigit timer values are used as defaults when dialing.
The Interdigit_Long_Timer is used after any one digit, if
all valid matching sequences in the dial plan are
incomplete as dialed. Range: 0–64 seconds.
Defaults to 10.
Interdigit Short Timer Short timeout between entering digits when dialing. The
Interdigit_Short_Timer is used after any one digit, if at
least one matching sequence is complete as dialed, but
more dialed digits would match other as yet incomplete
sequences. Range: 0–64 seconds.
Defaults to 3.