Avaya 555-233-128 IP Phone User Manual


 
Troubleshooting Guidelines
86 4600 Series IP Telephone Installation Guide
PWB SN cccccccccccc
cccccccc
Printed Wiring Board (circuit board) Serial
Number, up to 18 ASCII characters (which
display on both lines). Applies to all telephones
with a display except 4602, 4602SW, 4602SW+,
and 4610SW.
PWB
comcode
nnnnnnnnn 9 ASCII numeric characters: PWBCC. Applies to
all telephones with a display, except 4602,
4602SW, and 4610SW.
PWB version ccccccccc 9 ASCII numeric characters. Applies only to the
4602, 4602SW, 4602SW+, and 4610SW.
MAC
address
hh:hh:hh:hh:hh:hh Each octet of the MAC address displays as a
pair of hexadecimal numbers.
L2 tagging ccccccccc Up to 9 ASCII characters:
“on” if NVL2Q = 1
“off” if NVL2Q = 2
“auto: on” if NVL2Q = 0 and 802.1Q tagging is
on, and
“auto: off” if NVL2Q = 0 and 802.1Q tagging is
off.
VLAN ID cccc Up to 4 ASCII characters: L2QVLAN if 802.1Q
tagging is on and “none” if 802.1Q tagging is off.
IP Address nnn.nnn.nnn.nnn Up to 15 ASCII characters: IPADD.
Subnet mask nnn.nnn.nnn.nnn Up to 15 ASCII characters: NETMASK.
Router nnn.nnn.nnn.nnn Up to 15 ASCII characters: the IP Address of the
router in use.
File server nnn.nnn.nnn.nnn.nnnnn Up to 21 ASCII characters: the IP Address and
port of last file server used successfully during
initialization (“0.0.0.0” if no HTTP or TFTP file
server was used successfully).
Call server nnn.nnn.nnn.nnn.nnnnn Up to 21 ASCII characters: IP Address and port
of call server currently in use, if any, otherwise
“0.0.0.0”.
802.1X pass-thru mode
pass-thru with Logoff
Supplicant mode
If system parameter DOT1X = 0
If system parameter DOT1X = 1
If system parameter DOT1X = 2
Group nnn Up to 3 ASCII numeric characters: GROUP.
Table 2: Viewing Parameter Values (continued)
Name System Value Format
2 of 3