Avaya 555-233-128 IP Phone User Manual


 
Converting Software on Avaya 4600 Series IP Telephones
Issue 6 February 2007 43
Converting 4602+/4610SW/4620SW/4621SW IP Telephones
An H.323 IP telephone can be either in use with possible customized settings or out of the box
with factory default settings. An out of the box telephone requires accessing the manual
programming mode early in the process and setting the Signaling Protocol Identifier (SIG)
parameter to “SIP.” Converting to SIP early avoids having to first load H.323 software, log in,
and then invoke the “in use” process to load the SIP software.
Note:
Note: For information about the SIG parameter, see “Choosing the Right Application
File and Upgrade Script File” in the 4600 Series IP Telephone LAN Administrator
Guide (Document Number 555-233-507). For information on setting or changing
the SIG parameter, see Signaling Protocol Identifier
on page 77.
Table 1: H.323 to SIP and SIP to H.323 Conversion Chart
Environment
To convert this
type of telephone
To this type
of telephone
Then:
H.323-centric H.323 in use SIP Perform the Mute SIG procedure to
change the SIG parameter value from
default” to “2" (SIP).” For information,
see Signaling Protocol Identifier
on
page 77.
Press * to save the SIG parameter
change. Restart the telephone as
covered in Restart the Telephone
on
page 76.
H.323-centric H.323 factory set SIP Connect the telephone to a power
source and to the network.
As soon as you see the DHCP prompt,
press * to enter manual programming
mode. Press # multiple times to accept
the existing values until the telephone
displays “Enter command.”.
Perform the Mute SIG procedure and
change the value from “default” to “2"
(SIP).
Press * to save the SIG parameter
change. Restart the telephone as
covered in Restart the Telephone
on
page 76.
1 of 2