Aastra Telecom 480I IP Phone User Manual


 
Operational, Basic, and Advanced Parameters
41-001129-00 Rev 09, Release 1.4.1 A-51
Configuration Parameters
Appendix A
Parameter
sip lineN registrar port
Registrar Port
(in Web UI)
Aastra Web UI Advanced Settings->Line 1 thru 9
(480i/480i CT/9133i)
Aastra Web UI Advanced Settings->Global SIP (9112i)
Configuration Files aastra.cfg, <mac>.cfg
Description The registrar's port number
Format Integer
Default Value 0
Range Not Applicable
Example sip line1 registrar port: 5060
Parameter
sip linex backup registrar ip
Backup Registrar Server
(in Web UI)
Aastra Web UI Advanced Settings->LineN->
Basic SIP Network Settings
Configuration Files aastra.cfg, <mac>.cfg
Description The address of the backup registrar (typically, the backup SIP proxy) for
which the IP phone uses to send REGISTER requests if the primary
registrar is unavailable.
A global value of 0.0.0.0 disables backup registration. However, the
phone is still active and you can dial using username@ip address of the
phone.
If the backup registrar IP address is set to 0.0.0.0 for a per-line basis (i.e,
line 1, line 2, etc.), then the backup register request is not sent, the "No
Service" message does not display, and the message waiting indicator
(MWI) does not come on.
Format IP address or fully qualified Domain Name
Default Value 0.0.0.0
Range Not Applicable
Example sip line1 backup registrar ip: 192.168.0.102