40 Freedom Sequence Intelligent Power Manager Owner’s Guide
Freedom Sequence SCP Menu Map
Freedom Sequence SCP Menu Map
FSPM 00: Status
AC Src Type
AC Source
L1 Amps
L2 Amps
Batt Voltage
Circuit Status
Config
Advanced Settings
1-Ph
Shore1
0.0A
0.0A
12.0V
1 ACLoad1
1 Last Shed Current
2 ACLoad2
2 Last Shed Current
3 ACLoad3
3 Last Shed Current
4 ACLoad4
4 Last She Current
5 ACLoad5
5 Last Shed Current
6 ACLoad6
6 Last Shed Current
7 DCLoad1
7 Last Shed Current
8 DCLoad2
8 Last Shed Current
9 DCLoad3
9 Last She Current
10 DCLoad4
10 Last Shed Current
On 3.0A
6.0A
On 4.5A
4.0A
On 2.5A
2.5A
On 2.3A
2.0A
On 3.7A
1.0A
On 3.0A
4.0A
On N/A
N/A
On N/A
N/A
On N/A
N/A
On N/A
N/A
FSPM 00: Circuit Status
FSPM 00: Config
Mode
SHR BKR Mode
SHR BKR Rating
Circuit Config
Restore Defaults
[Operating]
[Auto]
[30.0A]
FSPM 00: Circuit Config
1 ACLoad1
1 Priority
1 Load Shed
2 ACLoad2
2 Priority
2 Load Shed
3 ACLoad3
3 Priority
3 Load Shed
4 ACLoad4
4 Priority
4 Load Shed
5 ACLoad5
5 Priority
5 Load Shed
Cont
[1]
[Enabled]
[2]
[Enabled]
[3]
[Enabled]
[4]
[Enabled]
[5]
[Enabled]
FSPM 00: Circuit Config
6 ACLoad6
6 Priority
6 Load Shed
7 DCLoad1
7 Priority
7 Load Shed
8 DCLoad2
8 Priority
8 Load Shed
9 DCLoad3
9 Priority
9 Load Shed
10 DCLoad4
10 Priority
10 Load Shed
[6]
[Enabled]
[7]
[Enabled]
[8]
[Enabled]
[9]
[Enabled]
[10]
[Enabled]
FSPM 00: Advanced Settings
BKR Rating
GEN BKR Rating
GEN Warmup Delay
Connect Seq Delay
AC Disq Priority
Nom DC Voltage
Circuit1
Circuit2
Circuit3
Circuit4
Circuit5
Circuit6
Circuit7
Circuit8
Circuit9
Circuit10
[Enabled]
[30.0A]
[0sec]
[10sec]
[2]
[12.0V]
FSPM 00: Circuit 1
Circuit Name
Load Shed
Circuit Type
AC Line
Priority
Reconnect MRGN
GEN Soft Start
Batt Low Trig Set
Batt Low Trig Clr
Batt High Trig Clr
Batt High Trig Set
[ACLoad1]
[Enabled]
[ACInputOut]
[Line1]
[2]
[10%]
[Disable]
[10.5V]
[11.0V]
[14.0V]
[14.5V]
1
10
11
A
B
C
D
E
F
G
H
I
J
K
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
[*Operating] or [Standby]
[*30.0] [5.0] to [50.0]
[*Auto] or [Manual]
[*30.0] [5.0] to [50.0]
[*0] [1] to [120]
[*10] [4] to [60]
[*1] [1] to [10]
[*12.0V] or [24.0V]
[*1] [1] to [10]
10
11
[*Enabled] or [Disabled]
[*Enabled] or [Disabled]
A
B
C
D
E
F
G
H
I
J
[*Enabled] or [Disabled]
[*ACInputOut] or [DCInputOut]
[*Line1] or [Line2] or [Batt1]
[*1] [1] to [10]
[*10] [1] to [100]
[*Disable] or [Enable]
[*10.5] [4.0] to [40.0]
[*11.0] [4.0] to [40.0]
[*14.0] [4.0] to [40.0]
[*14.5] [4.0] to [40.0]
K
[*ACLoad1]
NOTE: Circuit names can be up to ten characters long. Valid characters are from a to z, A to Z, 0 to 9,
symbols '/' (forward slash) and '–'(hyphen). Spaces, an underscore, and a period are not accepted
symbols. Examples are “Main-A/C” and “Refrigerat”.
see NOTE below
Settings
Device Status Screen
Freedom Sequence SCP Menu Map
NOTE: The Screens as shown in
this Menu Map are typical of the
six-circuit Freedom Sequence
model.
For example, in the Circuit Status
screen, a four-circuit Freedom
Sequence model will show only
eight circuits – four AC circuits
and four DC circuits.
FSequence IPM Owners Guide.book Page 40 Thursday, October 6, 2011 3:33 PM