Advanced Settings
AC Disqualification Priority
The Freedom Sequence power manager is capable of detecting a compatible
inverter/charger, such as the Freedom SW 2012 or the Freedom SW 3012,
that is connected on the Xanbus network. Upon detection, it initiates
inverter/charger interactive functions. The purpose of the AC Disq
Priority is to tell the inverter/charger when a critical load circuit is
disconnected due to an overload condition. Another purpose is to request
the inverter/charger to stop drawing any current for charging or to stop
powering the connected loads through the inverter/charger’s bypass circuit
if its battery is at high battery level.
The AC Disq Priority is any number between 1 to 10. This priority
number implies that, if an AC load with a circuit Priority number that is
the same or less than the AC Disq Priority number is ever disconnected
by Freedom Sequence due to an overload condition, then an “AC disqualify
request” is sent to the inverter/charger and that request is sustained until the
same AC load circuit gets reconnected somehow. The inverter/charger can
either accept this request and disqualify its incoming AC or reject the
request and keep drawing AC current.
For more information, see “Freedom Sequence Interaction with Other
Xanbus Devices” on page 39.
By default, the factory setting is set to 2.
NOTE: This setting can only be modified when Mode is set to Standby.
To change the AC disqualification priority from the Advanced
Settings screen:
FSPM 00: Status
L2 Amps
Batt Voltage
Circuit Status
Config
0.0A
12.8V
FSPM 00: Status
Batt Voltage
Circuit Status
Config
Advanced Settings
12.8V
FSPM 00: Advanced Settings
GEN BKR Rating
GEN Warmup Delay
Connect Seq Delay
AC Disc Priority
[30.0A]
[2sec]
[5sec]
[2]
FSPM 00: Advanced Settings
GEN BKR Rating
GEN Warmup Delay
Connect Seq Delay
AC Disc Priority
[30.0A]
[2sec]
[5sec]
[*2]
FSPM 00: Advanced Settings
GEN BKR Rating
GEN Warmup Delay
Connect Seq Delay
AC Disc Priority
[30.0A]
[2sec]
[5sec]
[1]
1 Press all three buttons to
enable Advanced Settings.
2 Scroll down to select
Advanced Settings.
5 Press to change
the setting.
6 Scroll up or down
to choose a value.
3 Press button.
7 Press to
confirm the
selected
value.
4 Scroll down
FSequence IPM Owners Guide.book Page 25 Thursday, October 6, 2011 3:33 PM