30 Freedom Sequence Intelligent Power Manager Owner’s Guide
Circuit Level Advanced Settings
Load Shed
The Load Shed setting here is the same as the setting discussed in “Load
Shed” on page 19. The only difference here is that the change in load shed
setting happens from the circuit-level screen in Advanced Settings
instead of from the Config screen.
Circuit Type
The Freedom Sequence power manager’s circuit relays can control either
AC or DC lines. If the circuit relay controls an AC line, its type is
ACInputOut. If the circuit relay controls a DC line, its type is DCInputOut.
AC relay types cannot be modified to DCInputOut. However, a DC relay
type can be modified to ACInputOut when that DC relay is used to control
an AC appliance.
AC Line
AC Relays All AC relays can be associated to either Line1 or Line2.
This is called Line Association. You may assign certain AC relays to
Line1 and the remaining AC relays to Line2. For example, Circuit1,
Circuit3, and Circuit5 can be assigned to Line1 and Circuit2,
Circuit4, and Circuit6 can be assigned to Line2. Default settings are
shown below.
DC Relays When the type of load circuit is changed from DC to AC, the
line association can either be Line1 or Line2. Default settings are shown
below.
NOTE: DC relays can be used to control AC loads. For example, a DC relay
can be used to signal an external AC contactor/relay to control an external
AC load circuit.
NOTE: This setting can only be modified when Mode is set to Standby.
Model AC Relays Types DC Relays Types
Four-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3,
Circuit4
ACInputOut
(default, cannot
be modified)
Circuit5,
Circuit6,
Circuit7,
Circuit8
DCInputOut
(default)
or
ACInputOut
Six-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3,
Circuit4,
Circuit5,
Circuit6
ACInputOut
(default, cannot
be modified)
Circuit7,
Circuit8,
Circuit9,
Circuit10
DCInputOut
(default)
or
ACInputOut
Model AC Relays Line Association
[Default]
DC Relays DC Conn
[Default]
Four-Circuit
Freedom
Sequence
Circuit1,
Circuit2
[Line1] Circuit5,
Circuit6
[Line1]
a
a.If the Type is changed to ACInputOut.
Circuit3,
Circuit4
[Line2] Circuit7,
Circuit8
[Line1]
a
Six-Circuit
Freedom
Sequence
Circuit1,
Circuit2,
Circuit3
[Line1] Circuit7,
Circuit8
[Line1]
a
Circuit4,
Circuit5,
Circuit6
[Line2] Circuit9,
Circuit10
[Line1]
a
FSequence IPM Owners Guide.book Page 30 Thursday, October 6, 2011 3:33 PM