Basic Configuration Settings
Shore Breaker Mode
Shore breaker setting can be set to Auto or Manual.
When set to Auto, the Freedom Sequence is capable of automatically
detecting the type of AC source (singe-phase or split-phase) and sets the
shore breaker rating (see “Breaker Ratings” on page 15). When split-phase
AC source is detected, a 50-amp breaker rating is automatically set.
Otherwise, if a single-phase AC source is detected, the breaker rating is set
to 30 amps. Because the setting is automatically determined, the shore
breaker rating cannot be modified.
When the shore breaker mode is set to Manual, the shore breaker rating can
be modified and set between 5 to 50 amps.
By default, the setting for Shore Breaker Mode is Auto.
To change the shore breaker mode from the Device Status screen:
FSPM 00: Status
L2 Amps
Batt Voltage
Circuit Status
Config
On 0.0A
12.8V
FSPM 00: Config
Mode
SHR BKR Mode
SHR BKR Rating
Circuit Config
[Operating]
[Auto]
[30.0A]
FSPM 00: Config
Mode
SHR BKR Mode
SHR BKR Rating
Circuit Config
[Operating]
[Manual]
[30.0A]
FSPM 00: Config
Mode
SHR BKR Mode
SHR BKR Rating
GEN BKR Rating
[Operating]
[*Auto]
[30.0A]
FSPM 00: Config
Mode
SHR BKR Mode
SHR BKR Rating
Circuit Config
[Operating]
[Manual]
[30.0A]
1 Press down until the
field is selected.
3 Scroll down.
5 Press to select a
new value.
6 Press to confirm
the new value.
2 Press to select
Config.
4 Press to change
the setting.