Page 88 ND-70917 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-DAID (DAI)
NOTE 3: When the source clock signal is supplied via the line between the Main Site and the
Remote Site, set the SW1-1 and SW1-2 as the following table. In this case, DAID cards
(DAID0, DAID1) must be mounted in PIM0.
NOTE 4: Time Slot Number 0 and 28 (TS0/28) cannot be used for control signal.
NOTE 5: This setting must be identical with the opposite DAIE card.
CONDITIONS
DAID0 DAID1 DAID2
REMARKS
SW
1-1
SW
1-2
SW
1-1
SW
1-2
SW
1-1
SW
1-2
One DAID card
is provided.
ON OFF
Clock signal is sent to
PLO0 of MP card via
Supply Route 0
(DAID0).
Two or three
DAID cards are
provided.
ON OFF OFF ON OFF OFF
Clock signal supply
route automatically
changes to Route 1
(DAID1), if a transmis-
sion line failure occurs
on Supply Route 0.