CHAPTER 3 TROUBLESHOOTING
NEAX2000 IVS
2
Remote PIM System Manual
ND-70917 (E), Issue 1.0
Page 59
PN-DAIB
(DAIB)
RUN lamp is not
flashing.
Abnormal operation
of DAIB card
1 Reset the MB switch.
(DownUpDown)
2 If the fault cannot be
cleared, replace the card.
LINK lamp is not on. Layer 2 link connec-
tion failure between
DAIA and DAIB
1 Check to see if the cable
between DAIA and DAIB is
correctly connected. Refer
to "Connection Between
Main Site and Remote Site"
on Page 47.
2 Reset the MB switch.
(DownUpDown)
RED lamp is on. PCM signal loss or
Frame Alignment
signal loss
1 Check to see if the cable
between DAIA and DAIB is
correctly connected. Refer
to "Connection Between
Main Site and Remote Site"
on Page 47.
2 Reset the MB switch of
DAIA card on the Main Site.
(DownUpDown)
RMT lamp is on. Remote alarm Check to see if the cable
between DAIA and DAIB
(sending side) is correctly con-
nected. Refer to "Connection
Between Main Site and
Remote Site" on Page 47.
Table 3-1 Remedial Action on Each Lamp Status (Continued)
CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION